Features
Technical Specifications
- DRVI32-09WF/ DRVO32-09
- Cooling Capacity 9.000 (2.730-12.620) Btu / h
- Cooling Capacity 2.6 (0.8-3.2) kWatt
- Heating Capacity 11.000 (2.730-14.330) Btu / h
- Heating Capacity 3.2 (0.8-4.2) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 2.6 kW
- Energy Class A+++
- SEER 8.5
- Annual Power Consumption 107 kWh / year
- Heating Middle Zone
- Pdesign 2.4 kW
- Energy Class A++
- SCOP 4.6
- Annual Power Consumption 731 kWh / year
- Heating Warm Zone
- Pdesign 2.6 kW
- Energy Class A+++
- SCOP 5.5
- Annual Power Consumption 662 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 2.9 (0.9-6.7) Α
- Current Input - Heating 3.6 (1.3-7.2) Α
- Power Input - Cooling 650 (200-1.500) W
- Power Input - Heating 800 (300-1.600) W
- Air Flow Volume (Turbo/High/Medium/Low) 650/600/500/450 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 20/25/30/35 db(A) - Noise Level - Outdoor unit 47 db(A)
- Sound Power Level - Indoor unit 54 db(A)
- Sound Power Level - Outdoor unit 59 db(A)
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 3 / 8”
- Power Supply Wire Outdoor / Fuses (Noxmm²)/(A) 3 × 1.5 / 10 No x mm² / Α
- Signal Wires 4 × 1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 887x211x281 mm -
Dimensions - Outdoor unit
(WxDxH) 800x280x550 mm -
Net Weight -
Indoor/Outdoor 10.0/29.0 kg - Refrigerant/Charge R32/650 g
-
Outdoor Operation
Temperature Range - Cooling -10~43 °C -
Outdoor Operation
Temperature Range - Heating -15~24 °C
- DRVI32-12WF/ DRVO32-12
- Cooling Capacity 12.000 (3.410-13.650) Btu / h
- Cooling Capacity 3.5 (1.0-4.0) kWatt
- Heating Capacity 14.500 (3.410-17.740) Btu / h
- Heating Capacity 4.2 (1.0-5.6) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 3.5 kW
- Energy Class A+++
- SEER 8.5
- Annual Power Consumption 144 kWh / year
- Heating Middle Zone
- Pdesign 2.8 kW
- Energy Class A++
- SCOP 4.6
- Annual Power Consumption 854 kWh / year
- Heating Warm Zone
- Pdesign 3.0 kW
- Energy Class A+++
- SCOP 5.5
- Annual Power Consumption 756 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 3.9 (1.4-6.7) Α
- Current Input - Heating 5.0 (1.3-7.2) Α
- Power Input - Cooling 875 (300-1.500) W
- Power Input - Heating 1.100 (500-1.600) W
- Air Flow Volume (Turbo/High/Medium/Low) 700/650/550/500 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 22/29/33/38 db(A) - Noise Level - Outdoor unit 48 db(A)
- Sound Power Level - Indoor unit 58 db(A)
- Sound Power Level - Outdoor unit 61 db(A)
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 3 / 8”
- Power Supply Wire Outdoor / Fuses (Noxmm²)/(A) 3 × 1.5 / 10 No x mm² / Α
- Signal Wires 4 × 1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 887x211x281 mm -
Dimensions - Outdoor unit
(WxDxH) 800x280x550 mm -
Net Weight -
Indoor/Outdoor 10.0/31.5 kg - Refrigerant/Charge R32/940 g
-
Outdoor Operation
Temperature Range - Cooling -10~43 °C -
Outdoor Operation
Temperature Range - Heating -15~24 °C
- DRVI32-18WF/ DRVO32-18
- Cooling Capacity 18.000 (4.430-19.790) Btu / h
- Cooling Capacity 5.0 (1.30-5.80) kWatt
- Heating Capacity 18.150 (4.770-20.470) Btu / h
- Heating Capacity 5.2 (1.4-6.0) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 5.0 kW
- Energy Class A++
- SEER 6.1
- Annual Power Consumption 287 kWh / year
- Heating Middle Zone
- Pdesign 4.6 kW
- Energy Class A+
- SCOP 4.0
- Annual Power Consumption 1.610 kWh / year
- Heating Warm Zone
- Pdesign 4.6 kW
- Energy Class A+++
- SCOP 5.1
- Annual Power Consumption 1.263 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 6.5 (1.8-8.9) Α
- Current Input - Heating 6.3 (2.3-11.3) Α
- Power Input - Cooling 1.460 (400-2.000) W
- Power Input - Heating 1.400 (520-2.500) W
- Air Flow Volume (Turbo/High/Medium/Low) 1.000/900/800/600 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 30/35/40/44 db(A) - Noise Level - Outdoor unit 53 db(A)
- Sound Power Level - Indoor unit 59 db(A)
- Sound Power Level - Outdoor unit 65 db(A)
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 1 / 2”
- Power Supply Wire Outdoor / Fuses (Noxmm²)/(A) 3 × 2.5 / 16 No x mm² / Α
- Signal Wires 4 × 1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 1.030x233x322 mm -
Dimensions - Outdoor unit
(WxDxH) 800x280x550 mm -
Net Weight -
Indoor/Outdoor 13.0/32.7 kg - Refrigerant/Charge R32/900 g
-
Outdoor Operation
Temperature Range - Cooling -10~43 °C -
Outdoor Operation
Temperature Range - Heating -15~24 °C
- DRVI32-24WF/ DRVO32-24
- Cooling Capacity 24.000 (7.500-29.000) Btu / h
- Cooling Capacity 7.0 (2.2-8.5) kWatt
- Heating Capacity 28.000 (8.190-34.120) Btu / h
- Heating Capacity 8.1 (2.40-10.0) kWatt
-
Seasonal Efficiency
(In accordance to EN14825) - Cooling
- Pdesign 7.0 kW
- Energy Class A++
- SEER 7.1
- Annual Power Consumption 350 kWh / year
- Heating Middle Zone
- Pdesign 5.6 kW
- Energy Class A+
- SCOP 4.0
- Annual Power Consumption 1.963 kWh / year
- Heating Warm Zone
- Pdesign 5.6 kW
- Energy Class A+++
- SCOP 5.1
- Annual Power Consumption 1.537 kWh / year
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 9.6 (3.2-13) Α
- Current Input - Heating 9.7 (3.2-13) Α
- Power Input - Cooling 2.160 (700-2.900) W
- Power Input - Heating 2.180 (700-2.900) W
- Air Flow Volume (Turbo/High/Medium/Low) 1.300/1.200/1.000/850 m³ / h
-
Noise Level - Indoor unit
(Silent/Low/Medium/High) 30/37/43/47 db(A) - Noise Level - Outdoor unit 52 db(A)
- Sound Power Level - Indoor unit 60 db(A)
- Sound Power Level - Outdoor unit 65 db(A)
- Compressor Type ROTARY
- Liquid line | Gas line 1 / 4” - 1 / 2”
- Power Supply Wire Outdoor / Fuses (Noxmm²)/(A) 3 × 2.5 / 16 No x mm² / Α
- Signal Wires 4 × 1.5 No x mm²
-
Dimensions - Indoor unit
(WxDxH) 1.115x248x336 mm -
Dimensions - Outdoor unit
(WxDxH) 890x353x697 mm -
Net Weight -
Indoor/Outdoor 16.0/51.0 kg - Refrigerant/Charge R32/1.200 g
-
Outdoor Operation
Temperature Range - Cooling -10~43 °C -
Outdoor Operation
Temperature Range - Heating -15~24 °C
Benefits
Ultra Silence Mode
Activate the Ultra Silence Mode and enjoy an absolute feeling of pure silence in your room.

Low Ambient Cooling at -10°C
The outdoor unit’s special design produces an efficient and effective cooling operation even at -10°C.
High Density Air Dust Filter
The exquisite filter optimizes the filtering effect by 40%.

24-hour Timer
Set the unit to start and stop automatically in a 24h period.

Sleep Mode
With the Sleep Mode, the air conditioner adjusts the room temperature for perfect sleeping conditions and great energy savings.

Auto Swing Louver
Distributes cool/warm air to maximum area by moving horizontal flaps automatically.
Louver Position Memory
Horizontal louver will automatically move to the same position as you set last time when the unit turned on
Anti-Cold Air Function
Indoor fan speed is regulated automatically from the lowest grade to the setting grade according to the evaporator temperature when the unit starts heating operation
Turbo Mode
This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Auto Restart
If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

Auto Error Diagnosis
Once abnormal operation or parts failure happens, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.

R32 ECO Refrigerant
The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.

More
Refrigerant Leakage Detect
Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected
Two-way Draining
Both left and right sides of the indoor unit are possible for drainage hose connection, easy for installation.
All DC Inverter
The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.
Lock
Engage the lock function to prevent anyone from changing the settings or children playing with the unit.
Media Library for Dark air conditioners
User & Installation, Remote Controller & Wi-Fi Manuals - Energy Labels - High Resolution Photos - Technical Specifications