Comfort series with Ultraviolet Type C Technology & Ionizer, Motion Sensor & 56°C Sterilization!

  • Effective protection against germs, bacteria and viruses thanks to the Ultraviolet Type C Technology & Ionizer function
  • Ideal temperature and energy saving with the Motion Sensor
  • Excellent atmosphere of perfect silence in your place
  • Impeccable air quality thanks to the efficient cleaning of the unit’s interior with the 56°C Sterilization
  • Control and operation of the air conditioner through the Inventor Control application

Ensure even distribution of air in all directions and cover even the most difficult parts of the room. The design of the series of air conditioners allows both horizontal and vertical movement of the blinds. Carefree & enjoy absolute comfort in every part of your home.

Meet your needs effectively, thanks to the special design for air distribution. Choose to diffuse air to the ceiling of the room for cooling mode to cool down quickly, avoiding exposure to cold air or to the floor in operation mode. heating, offering a warm atmosphere quickly. Enjoy ideal conditions in all seasons.

With the new ECO mode on your remote controller, you can set your air conditioner to operate at the lowest cost, achieving maximum energy savings & enjoying the greatest conditions in your place.

The technological superiority of the series guarantees excellent performances with the lowest operating costs. Take advantage of the highest energy class A+++ of Inventor air conditioners and create the perfect atmosphere exactly as you dream. At the same time save money while also taking care of the energy footprint by choosing an air conditioner with lower energy consumption.

A+++ Energy Class

The advanced coating of the outdoor unit with the special heating belt in its bottom surface and on the compressor, guarantees maximum protection under the most difficult weather conditions, ensuring the air conditioner lifeline extension and impeccable operation for excellent heating conditions in the place, in an instant and effective way. *This feature applies only for the outdoor units of 9.000/12.000/18.000 btu.

Avoid possible weather disasters in places that are not heated during the winter, in the most economical way. Turn on the 10°C function and the air conditioner will heat the room as needed, keeping the temperature constant at 10°C. Protect the items in your space and ensure low consumption with maximum energy savings during the winter.

It eliminates unwanted moisture in the indoor unit during cooling mode operation. After turning off the air conditioner, the indoor unit’s fan will keep running for a while in order to dry the indoor unit.

Powerful Self-Cleaning

The outdoor unit’s special design produces an efficient and effective heating operation even at -20°C.

The outdoor unit’s special design produces an efficient and effective cooling operation even at -20°C.

With the Sleep Mode, the air conditioner adjusts the room temperature for perfect sleeping conditions and great energy savings.

Sleep Mode
  • MFVI32-09WFI / MFVO32-09
  • Cooling Capacity 8.870 (2.730-10.920) Btu / h
  • Cooling Capacity Range 2.6 (0.8-3.2) kWatt
  • Heating Capacity 10.920 (2.730-14.330) Btu / h
  • Heating Capacity 3.2 (0.8-4.2) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 2.6 kW
  • Energy Class A+++
  • SEER 8.5
  • Energy Consumption 107 kWh / year
  • Heating Middle Zone
  • Pdesign 2.4 kW
  • Energy Class A++
  • SCOP 4.6
  • Energy Consumption 731 kWh / year
  • Heating Warm Zone
  • Pdesign 2.6 kW
  • Energy Class A+++
  • SCOP 5.5
  • Energy Consumption 662 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 2.9 (0.9-6.7) Α
  • Current Input Heating 3.6 (1.3-7.2) Α
  • Power Input Cooling 0.65 (0.2-1.5) kW
  • Power Input Heating 0.8 (0.3-1.6) kW
  • Air Flow Volume
    (Turbo/High/Medium/Low/Silent)
    650/600/500/350/250 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Medium / High) 16/25/32/38 db(A)
  • Noise Level Outdoor Unit 47 db(A)
  • Sound Power Level Indoor Unit 53 db(A)
  • Sound Power Level Outdoor Unit 59 db(A)
  • Dehumidifying Volume 1.2 L/h
  • Dehumidifying Volume 28.8 L/day
  • Compressor Type Panasonic
  • Liquid Line / Gas Line 1 / 4” | 3 / 8”
  • Power Supply Wire Outdoor 3 x 1.5 / 10 No x mm² / A
  • Signal Wires 4 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    856/197/300 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    800/275/553 mm
  • Net Weight Indoor / Outdoor 9.5/29.0 kg
  • Refrigerant / Charge R32 / 650 g
  • Operation Temperature Range Outdoor Unit Cooling -20~43 °C
  • Operation Temperature Range Outdoor Unit Heating -20~24 °C
  • MFVI32-12WFI / MFVO32-12
  • Cooling Capacity 11.940 (3.410-13.650) Btu / h
  • Cooling Capacity Range 3.5 (1.0-4.0) kWatt
  • Heating Capacity 14.330 (3.410-17.740) Btu / h
  • Heating Capacity 4.2 (1.0-5.2) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 3.5 kW
  • Energy Class A+++
  • SEER 8.5
  • Energy Consumption 144 kWh / year
  • Heating Middle Zone
  • Pdesign 2.8 kW
  • Energy Class A++
  • SCOP 4.6
  • Energy Consumption 854 kWh / year
  • Heating Warm Zone
  • Pdesign 3.0 kW
  • Energy Class A+++
  • SCOP 5.5
  • Energy Consumption 756 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 3.9 (1.4-6.7) Α
  • Current Input Heating 5.0 (2.3-7.2) Α
  • Power Input Cooling 0.88 (0.3-1.5) kW
  • Power Input Heating 1.1 (0.5-1.6) kW
  • Air Flow Volume
    (Turbo/High/Medium/Low/Silent)
    700/650/550/400/300 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Medium / High) 17/26/33/39 db(A)
  • Noise Level Outdoor Unit 48 db(A)
  • Sound Power Level Indoor Unit 55 db(A)
  • Sound Power Level Outdoor Unit 61 db(A)
  • Dehumidifying Volume 1.6 L/h
  • Dehumidifying Volume 38.4 L/day
  • Compressor Type Hitachi
  • Liquid Line / Gas Line 1 / 4” | 3 / 8”
  • Power Supply Wire Outdoor 3 x 1.5 / 10 No x mm² / A
  • Signal Wires 4 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    856/197/300 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    800/275/553 mm
  • Net Weight Indoor / Outdoor 9.5/31.5 kg
  • Refrigerant / Charge R32 / 940 g
  • Operation Temperature Range Outdoor Unit Cooling -20~43 °C
  • Operation Temperature Range Outdoor Unit Heating -20~24 °C
  • MFVI32-18WFI / MFVO32-18
  • Cooling Capacity 17.740 (4.770-20.470) Btu / h
  • Cooling Capacity Range 5.2 (1.4-6.0) kWatt
  • Heating Capacity 20.470 (4.770-23.540) Btu / h
  • Heating Capacity 6.0 (1.4-6.9) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 5.2 kW
  • Energy Class A++
  • SEER 7.2
  • Energy Consumption 253 kWh / year
  • Heating Middle Zone
  • Pdesign 4.6 kW
  • Energy Class A++
  • SCOP 4.6
  • Energy Consumption 1.401 kWh / year
  • Heating Warm Zone
  • Pdesign 4.8 kW
  • Energy Class A+++
  • SCOP 5.6
  • Energy Consumption 1.190 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 6.2 (1.8-8.9) Α
  • Current Input Heating 6.7 (2.3-10.9) Α
  • Power Input Cooling 1.4 (0.5-2.0) kW
  • Power Input Heating 1.5 (0.52-2.35) kW
  • Air Flow Volume
    (Turbo/High/Medium/Low/Silent)
    1.050/900/750/650/550 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Medium / High) 28/37/41/45 db(A)
  • Noise Level Outdoor Unit 51 db(A)
  • Sound Power Level Indoor Unit 57 db(A)
  • Sound Power Level Outdoor Unit 63 db(A)
  • Dehumidifying Volume 2.0 L/h
  • Dehumidifying Volume 48.0 L/day
  • Compressor Type Mitsubishi
  • Liquid Line / Gas Line 1 / 4” | 1 / 2”
  • Power Supply Wire Outdoor 3 x 2.5 / 16 No x mm² / A
  • Signal Wires 4 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    999/225/323 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    820/338/614 mm
  • Net Weight Indoor / Outdoor 12.0/37.8 kg
  • Refrigerant / Charge R32 / 950 g
  • Operation Temperature Range Outdoor Unit Cooling -20~43 °C
  • Operation Temperature Range Outdoor Unit Heating -20~24 °C
  • MFVI32-24WFI / MFVO32-24
  • Cooling Capacity 23.890 (7.510-25.600) Btu / h
  • Cooling Capacity Range 7.0 (2.2-7.5) kWatt
  • Heating Capacity 27.300 (8.190-29.000) Btu / h
  • Heating Capacity 8.0 (2.4-8.5) kWatt
  • Seasonal Efficiency
    (In accordance to ΕΝ14825)
  • Cooling
  • Pdesign 7.0 kW
  • Energy Class A++
  • SEER 7.0
  • Energy Consumption 345 kWh / year
  • Heating Middle Zone
  • Pdesign 5.6 kW
  • Energy Class A+
  • SCOP 4.0
  • Energy Consumption 1.959 kWh / year
  • Heating Warm Zone
  • Pdesign 5.2 kW
  • Energy Class A+++
  • SCOP 5.4
  • Energy Consumption 1.357 kWh / year
  • Voltage / Frequency / Phase 220 - 240 / 50 / 1 V / Hz / Ph
  • Current Input Cooling 9.6 (3.2-11.2) Α
  • Current Input Heating 9.6 (3.2-13.0) Α
  • Power Input Cooling 2.17 (0.7-2.5) kW
  • Power Input Heating 2.16 (0.7-2.9) kW
  • Air Flow Volume
    (Turbo/High/Medium/Low/Silent)
    1.250/1.100/950/850/700 m³ / h
  • Noise Level Indoor Unit (Silent / Low / Medium / High) 33/37/43/47 db(A)
  • Noise Level Outdoor Unit 60 db(A)
  • Sound Power Level Indoor Unit 60 db(A)
  • Sound Power Level Outdoor Unit 70 db(A)
  • Dehumidifying Volume 2.8 L/h
  • Dehumidifying Volume 67.2 L/day
  • Compressor Type Mitsubishi
  • Liquid Line / Gas Line 3 / 8” | 5 / 8”
  • Power Supply Wire Outdoor 3 x 2.5 / 16 No x mm² / A
  • Signal Wires 4 × 1.5 No x mm²
  • Dimensions
    Indoor Unit
    (WxDxH)
    1.115/235/343 mm
  • Dimensions
    Outdoor Unit
    (WxDxH)
    890/353/697 mm
  • Net Weight Indoor / Outdoor 15.2/45.0 kg
  • Refrigerant / Charge R32 / 1.300 g
  • Operation Temperature Range Outdoor Unit Cooling -20~43 °C
  • Operation Temperature Range Outdoor Unit Heating -20~24 °C

This function gives you a boost in cooling and heating power for a period and makes the room cool down or heat up rapidly.

Horizontal louver will automatically move to the same position as you set last time when the unit turned on

If the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.

The exquisite filter optimizes the filtering effect by 40%.

Indoor unit will show error code “EC” and will stop automatically when refrigerant leakage is detected

The fan motors of the indoor and outdoor units as well as the compressor have been upgraded to All DC Inverter technology. In this way, the compressor can change the capacity depending on the needs of the indoor atmosphere and create perfect conditions in your space.

The R32 ECO Refrigerant with 68% lower global warming potential, is here to significantly enhance your air conditioner performance and to drastically contribute to global warming protection. It does not adversely affect the ozone layer, contributes in reducing global warming effect by entrapping smaller amounts of heat (GWP = 675) and can be easily reused and recycled.

Media Library - COMFORT

User, Remote Control & Installation Manuals - Energy Labels - Pdesign Test Reports - Service Manuals - High Resolution Photos